Range: 

   Wall Mounted Unit
   INVERTER

Reverse Cycle (Heating & Cooling)

FTXS20L FTXS25L
FTXS35L FTXS46L
FTXS50L FTXS60L
FTXS71L FTXS85L
FTXS95L

Cooling Only

FTKS20L FTKS25L
FTKS35L FTKS50L
FTKS60L FTKS71L

DC INVERTER.ai

Info

 

Standby Power Function InfoStandby Power Function. When the air conditioner is not in use, the standby power function turns off power supply to the outdoor unit and sets the indoor unit into standby energy saving mode, reducing energy consumption.

 

Power-Airflow Dual Flaps InfoPower-Airflow Dual Flaps. Power-airflow dual flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.

 

Wide Angle Louvres InfoWide Angle Louvres. Smoothly curved wide angle louvres provide wide airflow coverage for effective cooling/heating operation.

 

Vertical Auto-Swing
(up and down) InfoVertical Auto-Swing. This function automatically moves the flaps up and down to distribute air across the room.

 

Horizontal Auto-Swing
(left and right) InfoHorizontal Auto-Swing. This function automatically moves the louvres to the left and right to cover the room with cool/warm air.

 

3-D Airflow Info3-D Airflow. Combines vertical and horizontal auto-swing to circulate cool/warm air to the corners of large spaces.

 

Comfortable Mode InfoComfortable Mode. The new flap changes the delivery angle to horizontal for cooling and vertical for heating operation, to prevent cold or warm air from blowing directly onto your body.

 

Indoor Unit Quiet Operation InfoIndoor Unit Quiet Operation Function. Sound levels are reduced by 2-3 decibels (dB) from the low fan speed for quieter heating and cooling**.

 

Outdoor Unit Quiet Operation InfoOutdoor Unit Quiet Operation Function. Outdoor unit sound levels can be reduced by 3dB for times when quieter operation is needed.

 

Intelligent Eye InfoIntelligent Eye. This is an infrared motion sensor with the ability to sense movement in the room.  When you are in the room, the air conditioner operates normally.  If no activity is detected in a room for more than 20 minutes the air conditioner automatically changes to an energy-saving operation.

 

Automatic Operation InfoAutomatic Operation (reverse cycle only). For year-round comfort, this function allows the unit to automatically switch between heating and cooling modes as required.

✓*
 

Program Dry Function InfoProgram Dry Function. The system reduces the humidity in the room while maintaining the temperature as much as possible.  It automatically controls the temperature and airflow rate and will switch into cooling mode if the room temperature increases too much.

 

Auto Fan Speed InfoAuto Fan Speed. To reduce operating noise, the fan speed is automatically controlled by the micro-processor to suit the thermostat setting and prevailing room temperature.

 

Hot Start  InfoHot Start. When heating commences, or when changing from cooling to heating, airflow doesn't start until the air is warm, preventing cold draughts.

✓*
 

Automatic Defrost  InfoAutomatic Defrost. During heating operation in low ambient temperature conditions, frost can form on the outdoor unit heat exchanger which can reduce your air conditioner’s performance. Daikin’s intelligent defrost system constantly monitors a range of system parameters and temperatures to determine the optimum time to commence a defrost operation for maximum performance in cold conditions.

 

Titanium Apatite Photocatalytic Air-Purifying Filter InfoAir-Purifying Filter. Traps most microscopic particles and decomposes odours to purify the air in your room.

 

Air-Purifying Filter InfoAir-Purifying Filter. Traps microscopic particles and decomposes odours to purify the air in your room.

 

Wipe Clean InfoWipe Clean. The panels of the air conditioner can be cleaned with a cloth across the smooth surface.

 

Econo Mode InfoEcono Mode. Controls the upper limit of frequency, reducing power consumption. This reduces the load on the electrical circuit when multiple electrical devices are used simultaneously.

 

Powerful Operation InfoPowerful Operation. Pushing the POWERFUL button on the remote control gives you a boost in cooling and heating power for a 20-minute period, even if the unit is already operating at high capacity.

 

LCD Wireless Remote Control

 

Indoor Unit On/Off Switch

 

24-Hour On/Off Timer Info24-Hour On/Off Timer. The timer can be preset to start and stop the air conditioner at any time within a 24-hour period. Once the times are set, the air conditioner can be operated for a period by simply pressing the ON or OFF timer buttons.

 

Weekly Timer InfoWeekly Timer. This function makes it easy to enter up to four settings per day for each day of the week. It not only allows you to program on and off time, but also the desired temperature.

 

Night Set Mode InfoNight Set Mode. Through the use of the ‘Timer-OFF Circuit’, the preset room temperature gently rises in cooling or falls in heating before the unit stops. This energy efficient feature allows you to sleep comfortably without feeling a sudden change in the room temperature.

 

Auto-Restart after Power Failure InfoAuto-Restart. The unit memorises the operation mode, airflow and temperature settings. Should there be a power failure when the unit is in operation, it will automatically return to the same operating conditions when the power is restored.

 

Self-Diagnosis with Digital Display InfoSelf-Diagnosis. In the unlikely event that a problem develops with the unit, malfunction codes can be displayed on the liquid crystal panel of the remote control for fast and easy fault diagnosis.

 

Anti-Corrosion Treatment of
Outdoor Heat Exchanger Fin InfoAnti-Corrosion Treatment. The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric corrosion.

* Only available in Reverse Cycle models
** Capacity may decrease when selected

Controller: 

Backlit Wireless Remote Controller (FTXS, and FTKS range)

This remote controller a with backlit liquid crystal display and four luminescent control buttons for major features, also features a built-in weekly time clock that can be programmed to suit your personal lifestyle with up to four actions per day of the week. This advanced controller not only allows you to program on/off time, but also the desired temperature. Futhermore, the copy function enables any daily program to be replicated on any other day or days as required.

Other functions include:

  • 24 Hour timer
  • Weekly timer
  • Night set mode
  • Self diagnosis with digital display
  • Comfortable mode
  • Econo mode

LCD Wireless Remote Controller (FTYN and FTN range)

This remote controller puts superior comfort at your fingertips. Frequently used buttons are instantly accessible while other buttons are under the cover of the remote. A large liquid crystal display panel makes it easy to read the settings and the on/off button has a raised dot so that you can feel it in the dark.

Other functions include:

  • 24 Hour Timer
  • Night set mode
  • Self diagnosis with digital display
  • Comfortable mode

 

 

 

Tech Specs: 

 L-Series Inverter: Reverse Cycle

INDOOR UNIT  FTXS20LVMA FTXS25LVMA FTXS35LVMA FTXS46LVMA FTXS50LVMA FTXS60LVMA FTXS71LVMA FTXS85LVMA FTXS95LVMA
OUTDOOR UNIT  RXS20LVMA RXS25LVMA RXS35LVMA RXS46LVMA RXS50LVMA RXS60LVMA RXS71LVMA RXS85LVMA RXS95LVMA
Rated Capacity Cool (kW) 2 2.5 3.5 4.6 5.0 6.0 7.1 8.5 9.4
Heat (kW) 2.7 3.4 4.0 5.1 6.0 7.0 8.0 9.0 10.5
Capacity Range Cool (kW) 1.3-2.8 1.3-3.2 1.4-4.0 1.7-5.3 1.7-6.0 1.7-6.7 2.3-8.5 3.0-10.5 3.0-11.2
Heat (kW) 1.3-4.3 1.3-4.7 1.4-5.2 1.7-6.8 1.7-7.7 1.7-8.0 2.3-10.0 3.0-11.2 3.0-11.7
Indoor Airflow Rate (Hi) Cool (l/s) 162 177 188 203 305 320 352 397  378
Heat (l/s) 175 192 200 215 323 353 360 402 415
Indoor Fan Speeds C/H 5 steps, quiet and automatic
Energy Label/Star Ratings Cool 4 4.5 3 2.5 3 2.5 2 2 2
Heat 4 5 4.5 2.5 3.5 3.5 2.5 2.5 2
Front Panel Colour   White
Power Supply    1 phase, 220-240, 50Hz
Power Input (Rated) Cool (kW) 0.45 0.54 0.91 1.25 1.32 1.69 2.08 2.58 2.88
Heat (kW) 0.61 0.70 0.88 1.37 1.47 1.73 2.18 2.51 3.22
E.E.R / C.O.P Cool/Heat 4.44/4.43 4.63/4.86 3.85/4.55 3.68/3.72 3.79/4.08 3.55/4.05 3.41/3.67 3.29/3.59 3.26/3.26
A.E.E.R / A.C.O.P Cool/Heat 4.37/4.37 4.57/4.81 3.82/4.51 3.66/3.70 3.77/4.06 3.53/4.03 3.40/3.66 3.28/3.57 3.25/3.25
Dimensions (HxWxD) Indoor (mm) 295x800x215 340x1050x248 340x1200x240
Outdoor (mm) 550x765x285 735x825x300 770x900x320 990x940x320
Weight Indoor (kg) 9 10 10 10 14 14 14 17 18
Outdoor (kg) 31 34 34 46 46 46 71 80 82
Compressor Type   Hermetically sealed swing type
Refrigerant Type   R410A
Max Pipe Length (m) 20 30
Max Level Difference (m) 15 20
Pre Charged Length (m) 10
Pipe Sizes Liquid (mm) 6.4 9.5
Gas (mm) 9.5 12.7 15.9
Drain
(O.D. mm)
16.0
Outdoor Operative Range (Outdoor Temp) Cool (CDB)  10 to 46
Heat (CWB)

-15 to 18

Indoor Sound Level (H/SL) Cool (dBA) 38/22 40/22 42/23 44/32 46/32 48/33 51/34 49/37 51/38
Heat (dBA) 39/25 40/25 42/26 42/30 45/30 48/30 49/32 49/35 50/35
Outdoor Sound Level (H/SL) Cool (dBA) 46/43 47/43 49/44 47/44 47/44 49/46 52/49 54/51 54/50
Heat (dBA) 47/44 48/44 49/45 48/45 48/45 49/46 53/49 55/51 55/51
EPA Sound Power Level (H) Outdoor (dBA) Cool/Heat 60/61 61/62 63/63 61/62 61/62 63/63 66/67 68/69 68/69

L-Series Inverter: Cooling Only

INDOOR UNIT   FTKS20LVMA FTKS25LVMA FTKS35LVMA FTKS46LVMA FTKS50LVMA FTKS60LVMA FTKS71LVMA
OUTDOOR UNIT   RKS20LVMA RKS25LVMA RKS35LVMA RKS46LVMA RKS50LVMA RKS60LVMA RKS71LVMA
Rated Capacity Cool (kW) 2.0 2.5 3.5 4.6 5.0 6.0 7.1
Capacity Range Cool (kW) 1.3-2.8 1.3-3.2 1.4-4.0 1.7-5.3 1.7-6.0 1.7-6.7 2.3-8.5
Indoor Airflow Rate (Hi) Cool (kW) 162 177 188 203 305 320 352
Indoor Fan Speeds   5 steps, quiet and automatic
Energy Label / Star Ratings Cool 4 4.5 3 2.5 3 2.5 2
Front Panel Colour   White
Power Supply   1 phase, 220-240, 50Hz
Power Input (Rated) Cool (kW) 0.45 0.54 0.91 1.25 1.32 1.69 2.08
E.E.R / C.O.P Cool 4.44 4.63 3.85 3.68 3.79 3.55 3.41
A.E.E.R / A.C.O.P Cool 4.37 4.56 3.82 3.66 3.77 3.53 3.40
Dimensions (HxWxD) Indoor (mm) 295x800x215 295x800x215 295x800x215 295x800x215 340x1050x248 340x1050x248 340x1050x248
Outdoor (mm) 550x765x285 550x765x285 550x765x285 735x825x300 735x825x300 735x825x300 770x900x320
Weight Indoor (kg) 9 10 10 10 14 14 14
Outdoor (kg) 31 34 34 46 46 46 71
Compressor Type   Hermetically sealed swing type
Refrigerant Type   R410A
Max Pipe Length (m) 20 30
Max Level Difference (m) 15 20
Pre Charged Length (m) 10
Pipe Sizes Liquid (mm) 6.4 9.5
Gas (mm) 9.5 12.7 15.9
Drain
(O.D. mm)
16
Outdoor Operating Range (Outdoor Temp) Cool (CDB) 10 to 46
Indoor Sound Level (H/SL) Cool (dBA) 38/22 40/22 42/23 44/32 46/32 48/33 49/34
Outdoor Sound Level (H/SL) Cool (dBA) 46/43 47/43 49/44 47/44 47/44 49/46 52/49
EPA Sound Power Level (H) Outdoor (dBA) Cool 60 61 63 61 61 63 66
 

Product Brochure: 

Download Brochure

 
Download Adobe Reader You need the program Adobe Acrobat or Adobe Acrobat Reader to open the documents. The program Adobe Acrobat Reader is a freeware program and can be downloaded from www.adobe.com

Product Support: